8 outputs (9 from version 3.03) which can be flexibly configure to operate 1 to 8-part variable ratio nutrient dosing, pH raise, pH lower, Irrigation, add water and alarm
Output voltage same as supplied voltage 12V to 24V AC or DC. Normally 24V DC supplied Nutrient measurement units EC, CF or ppm (EC x 500)
Measured range 0.00 to 9.99EC, 0.1 to 99.9CF, 0 to 4999 ppm Nutrient resolution 0.01 mS/cm, 0.1 CF, 5ppm
Nutrient measurement accuracy +/- 0.1 EC, 1.0 CF or 50ppm - temperature compensated Nutrient dosing range 0.10EC to 5.99EC, 0.1 to 59.9CF, 50ppm to 2999 ppm
pH resolution and accuracy – 0.1 pH pH measurement range 2pH to 12pH pH dosing range 4.5pH to 8pH
Temperature resolution and accuracy 1°C, 2°F
Temperature measuring range 0-50°C, 32-125 °F
Operating temperature range 0-45°C, 32-110°F (and not in direct sunlight)
Power source – mains transformer pack supplied; specify mains voltage and pin type (power to controller can be between 12V and 24V either AC or DC to suit the output devices) Outputs will have the same voltage as the supplied voltage from the power pack.
Large graphics display using simple four key interface
Nutrient sensor uses DiPulseTM technique to resist fouling
Dosing fail safe shut-off (can be disabled)
if nutrient is below 0.1EC, 1CF, 50ppm
if pH below 4.5pH or above 8.0pH
if sensor fault detected (some pH faults cannot be detected) USB connection and software supports multiple controllers Sample pot supplied.
Valves available separately with cables and flow restricting pipes Valves chemically resistant to 5% Phosphoric acid, 2% Nitric acid
Compatible triple peristaltic pumps available separately as an alternative to solenoid valves.